LiliF Diagnostic KitsMore Simple, More Accurate, More Effective

Veterinary MDx

LiliF® AIV 5/7/9 Multi qRT-PCR Kit

Cat.No Capacity Inquire
IP15007 96 tests Inquire
PRODUCT INFORMATION
Description

A multiplex real-time RT-PCR solution for rapid and reliable detection of avian influenza virus H5, H7, and H9 subtypes.

    • Simultaneously detects the HA gene of avian influenza virus H5, H7, and H9 subtypes in a single real-time RT-PCR run.
    • Provides a streamlined workflow with an approximately 1-hour protocol.
    • Can be used alongside LiliF® AIV M Real-time RT-PCR Kit (fast ver.) for concurrent HA- and M-gene detection.
    • Validated with chicken and duck oropharyngeal swabs, cloacal swabs, feces, and tissue homogenates.
    • Demonstrated 100% clinical sensitivity and 100% clinical specificity in the reported clinical evaluation.
    • No cross-reactivity was observed with the tested avian pathogens, including NDV, IBV, IBDV, Salmonella enteritidis, Bacillus cereus, and Escherichia coli.

LiliF® AIV 5/7/9 Multi qRT-PCR Kit is a qualitative real-time RT-PCR assay designed for the detection of the hemagglutinin (HA) gene of avian influenza virus H5, H7, and H9 subtypes. Its multiplex format supports subtype detection in a single run, helping streamline molecular testing workflows.

The kit uses an approximately 1-hour protocol and can be run alongside the LiliF® AIV M Real-time RT-PCR Kit (fast ver.) to support concurrent detection of the HA and M genes. Clinical evaluation included multiple sample types from chickens and ducks, with no PCR inhibition reported in the evaluated samples and no observed interference between subtype channels.

Applications

01

Qualitative detection of avian influenza virus H5, H7, and H9 subtypes

02

Testing of oropharyngeal swabs, cloacal swabs, feces, and tissue homogenates from chickens and ducks

03

Concurrent HA-gene and M-gene detection when used with LiliF® AIV M Real-time RT-PCR Kit (fast ver.)

04

Molecular surveillance and veterinary diagnostic workflows for avian influenza virus

Kit Contents
Contents Quantity
AIV 5/7/9 Multi qRT-PCR PreMix 20 μl × 96 tubes
Positive Control 25 μl × 3 tubes
DNase/RNase-Free Water (Negative Control) 1 ml × 1 tube
Instructions for Use 1 copy
Technical Data

Consistent Detection Across Sample Types

The kit was evaluated using clinical sample types including oropharyngeal swabs, cloacal swabs, feces, and tissue homogenates from chickens and ducks. The reported evaluation found consistent target detection across the tested sample types, with no PCR inhibition reported.

 

Shorter Testing Time with Comparable Diagnostic Performance

Compared with the company's existing separate LiliF® AIV H5 and LiliF® AIV H7 Real-time RT-PCR Kits, the reported workflow reduces the testing time from approximately 2 hours 10 minutes to within 1 hour, while maintaining equivalent sensitivity and specificity in the evaluated clinical samples.


 

Clinical Performance: 100% Sensitivity and Specificity


 

Analytical Specificity

No cross-reactivity was observed with the tested viral pathogens, including Newcastle disease virus (NDV), infectious bronchitis virus (IBV), and infectious bursal disease virus (IBDV), or with the tested bacterial pathogens, including Salmonella enteritidis, Bacillus cereus, and Escherichia coli.

TroubleShooting Guide
Q
What should I do if the Positive Control (PC) does not show the expected amplification?
A
Verify that the Positive Control was added correctly and that the prescribed reaction volume and qRT-PCR conditions were followed. Ensure that the AIV 5/7/9 Multi qRT-PCR PreMix was completely thawed and briefly centrifuged before use. Confirm that the kit was stored at ≤ −20°C and has not exceeded its expiration date or recommended period after first opening. If the Positive Control continues to fail, repeat the test using fresh kit components and verify the instrument settings.
Q
Why is amplification detected in the Negative Control (NC)?
A
Amplification in the Negative Control may indicate contamination of the reaction system. Use the supplied DNase/RNase-free water as the Negative Control and handle it separately from the Positive Control and specimens. Prepare reactions in a clean work area, use filter tips, and avoid transferring material between tubes. Decontaminate the work area and repeat the test with fresh reagents. Do not interpret results from a run with suspected contamination until the cause has been addressed.
Q
What does it mean if the Internal Positive Control (IPC, HEX) is not detected?
A
The IPC is an exogenous DNA control independent of specimen type. For specimens without strong positive target signals, an absent IPC signal may indicate a problem with the test process or possible PCR inhibition. Review the nucleic acid extraction procedure, specimen quality, reagent handling, and reaction setup before repeating the test. However, in strongly positive specimens, failure to detect the IPC does not affect interpretation of the positive target result, as specified in the product instructions.
Q
Why is no amplification detected for H5, H7, or H9 in a specimen?
A
Confirm that the specimen was collected and stored appropriately and that nucleic acid extraction was performed according to the extraction kit manufacturer's instructions. Testing immediately after extraction is recommended. Verify that the correct fluorescence channels and cycling conditions were selected, including signal acquisition at 60°C for 15 seconds during amplification. PCR inhibitors or sequence variation in the target region may contribute to false-negative results. Review the IPC and control results before interpreting the specimen as negative.
Q
How should results near the cut-off values be interpreted?
A
Interpret results using the target-specific cut-off values established for the CFX96 system: H5 (FAM), Ct ≤ 38; H7 (Cy5), Ct ≤ 35; and H9 (Texas Red), Ct ≤ 36. Values above the applicable cut-off or with no Ct are interpreted as negative according to the product instructions. Confirm that the baseline and threshold settings are set to Auto and that the correct fluorescence channel is assigned to each target. If the result is inconsistent with other findings, review the controls and consider repeat testing in accordance with the laboratory's procedures.
Q
Why are the Ct values different between runs or instruments?
A
Differences in specimen handling, nucleic acid extraction, pipetting, reagent storage, and instrument settings may affect test results. Ensure that each reaction contains 20 µL of AIV 5/7/9 Multi qRT-PCR PreMix and 5 µL of specimen RNA, Positive Control, or Negative Control, as appropriate. Mix thoroughly and briefly centrifuge the tubes to remove air bubbles and collect the reaction mixture at the bottom. Use consistent instrument settings and avoid repeated freeze-thaw cycles. Note that the reported Ct values exclude the five pre-amplification cycles and are intended for qualitative interpretation, not quantitative analysis.
```
Related Product
관련제품 Product,No,Capacity,Inquire list
Product Cat.No Capacity inquire
LiliF® AIV H5 Real-time RT-PCR Kit Best
IP15005 48 tests Inquire
LiliF® AIV H7 Real-time RT-PCR Kit Best
IP15006 48 tests Inquire
LiliF® AIV M Real-time RT-PCR Kit Best
IP15004 48 tests Inquire
LiliF® AIV HA (1-16) Multi-tube RT-PCR Kit
IPC12020 6 tests Inquire
LiliF® AIV M Real-time RT-PCR Kit (Fast ver.) New
IP15008 96 tests Inquire
Protocol

List

TOP