SupportCustomer support service

iNRON Magazine

High Sensitivity in 30 Mins
Date 16-Nov-26 Hit 616
Patho Gene-spin™ Series:
Dual-Track Pathogen DNA / RNA Extraction
Engineered for veterinary diagnostics, pathogen surveillance, and clinical research. Choose between the proven, cost-effective Patho Gene-spin™ for standard screening workflows and the enhanced Patho Gene-spin™ HS formulated with lyophilized Proteinase K and Carrier RNA for maximized recovery from low-titer pathogens and difficult matrices.
Low-Titer Sensitivity
95% Clinical Recovery
Ct Value Boost
ΔCt > 2 - 3 Cycles
Fast Protocol
Within 30 Minutes
HS Formulation
Proteinase K + Carrier RNA
1
Dual-Track Extraction Systems Comparison
Optimized silica spin-column chemistries designed for daily routine diagnostic screening and high-sensitivity trace pathogen isolation.
Standard Routine Workflow
Patho Gene-spin™ DNA/RNA Extraction Kit
Centrifuge-based spin column protocol for universal viral DNA/RNA and bacterial gDNA isolation. Tailored for daily diagnostic screening across serum, plasma, cell culture, and body fluid specimens with standard 50 μL elution.
High-Sensitivity (HS) Platform
Patho Gene-spin™ HS DNA/RNA Extraction Kit
Advanced formulation incorporating lyophilized Proteinase K and Carrier RNA. Engineered for low-titer pathogens, stool, whole blood, and difficult matrices with high inhibitor loads and flexible 40 – 50 μL elution.
2
Why Upgrade to Patho Gene-spin™ HS?
Engineered specifically to solve the dual challenges of trace nucleic acid loss on spin columns and enzymatic inhibition in complex biological samples.
Trace Recovery Shield
Lyophilized Carrier RNA Included
Suppresses non-specific binding of ultra-low viral RNA to silica spin columns while acting as a competitive decoy against endogenous RNases, significantly boosting yield from low-titer specimens.
Matrix Lysis Power
Active Proteinase K Digestion
Rapidly degrades protective viral capsids, cell envelope proteins, nucleases, and protein inhibitors at 56 °C within 10 minutes. Essential for whole blood, thick stool homogenates, and tissue lysates.
Sensitivity Tuner
Flexible 40 – 50 μL Elution
Standard 50 μL elution maximizes total recovered nucleic acids, while compact 40 μL elution concentrates purified DNA/RNA to achieve higher template copy density per μL in downstream qPCR.
3
Empirical Performance Validation across 7 Pathogens
Rigorous comparative testing demonstrates over 20% sensitivity enhancement in low-titer clinical matrices, with earlier qPCR detection across viral RNA and bacterial DNA targets.
Low-Titer Diagnostic Concordance (n = 42)
Diagnostic Recovery Rate: 74% → 95% (+21% Boost)
Evaluating challenging low-titer samples across whole blood, stool, and vaccines demonstrated marked detection improvements (>2 Ct for β-Coronavirus RNA, >3 Ct for C. chauvoei DNA).
95.2% Sensitivity
Pathogen Category Representative Verified Strains Validated Matrices
Enveloped Viruses Pestivirus, β-Coronavirus, PRRSV Whole blood, serum, stool, nasal swabs
Non-Enveloped Viruses Infectious Bursal Disease Virus (IBDV), Rotavirus Fecal suspension, cloacal swabs, tissue
Gram(+) Bacteria Clostridium sp. (C. chauvoei) Stool, tissue homogenate, bacterial pellet
Gram(−) Bacteria Salmonella sp. Whole blood, urine, cloacal swabs, broth culture
4
Simple 4-Step Protocol: Total ≤ 30 Minutes
Fast, centrifuge-based spin-column protocol requires no hazardous organic extractions or ethanol precipitation.
STEP 1
Lysis & Digestion
56 °C for 10 min
Add sample, Proteinase K, Carrier RNA, and Lysis Buffer. Incubate to completely digest capsids and nucleases.
STEP 2
Membrane Binding
1 min centrifugation
Add Binding Buffer, load onto silica spin column, and centrifuge. Target DNA and RNA selectively bind to the matrix.
STEP 3
2-Step Washing
Inhibitor elimination
Wash with Washing Buffer A and Buffer B to eliminate proteins, salts, heme, bile salts, and other PCR inhibitors.
STEP 4
Elution & Storage
40 – 50 μL eluate
Elute with 40-50 μL Elution Buffer. High-purity pathogen DNA/RNA is ready for immediate qPCR, RT-qPCR, or deep sequencing.
5
Ordering Information & Downstream Pairing
Fully validated pairing with iNtRON's real-time PCR amplification systems and veterinary diagnostic assays.
Cat. No. Product Name Size Key Components Details
17154 Patho Gene-spin™ DNA/RNA Extraction Kit
Standard spin-column pathogen kit for routine diagnostic screening
50 preps
(200 preps: 17154.2)
Spin columns, Lysis Buffer, Wash A/B, Elution View →
17156 Patho Gene-spin™ HS DNA/RNA Extraction Kit
High-sensitivity formulation with Proteinase K & Carrier RNA for trace pathogens
50 preps + Proteinase K & Carrier RNA (Lyophilized) View →
iNtRON Biotechnology, Inc. • Molecular Diagnostics Division
137 Sagimakgol-ro, Jungwon-gu, Seongnam-si, Gyeonggi-do 13202, Republic of Korea
Tel: +82-31-739-5741 | Fax: +82-31-739-5264 | E-mail: tech@intronbio.com
• © 2026 iNtRON Biotechnology, Inc. All rights reserved.

List

TOP